Product Description
The Warmup DWS loose wire underfloor heating system uses a 1.8mm cable, The small cross-section of the element allows it to be installed quickly without the need for a layer of screed, eliminating any raising floor levels. The use of the ultra-thin dual-core flexible wire in this system makes it ideal for irregular shaped areas.
Loose wire heating systems are perfect for installation under ceramic or natural stone tiled floors. Installing Warmup loose wire removes any need to dig up the floor. The heating element can simply be fixed to the subfloor and tiled on top of.
Specification
Heater construction | Dual core earth screened cable |
---|---|
Operating voltage | 220 - 240V, 50Hz |
Cable thickness | 2mm |
Inner insulation | ECTFE (advanced fluoropolymers) |
Outer insulation | ECTFE (Advanced Fluoropolymers) |
Average output rating | 150 W/m2 |
Cold tail length (connection lead) | 3m |
Approvals | ASTA BEAB component, KEMA and GS |
Area m2 | Heaters required | Spacing |
---|---|---|
1.5 - 1.8 | DWS300 | 70 |
1.9 - 2.4 | DWS300 | 90 |
2.5 - 2.7 | DWS400 | 70 |
2.8 - 3.0 | DWS400 | 80 |
3.1 - 3.4 | DWS400 | 90 |
3.5 - 3.8 | DWS600 | 70 |
3.9 - 4.1 | DWS600 | 80 |
4.2 - 4.4 | DWS600 | 90 |
4.5 - 5.0 | DWS800 | 70 |
5.1 - 5.6 | DWS800 | 80 |
5.7 - 5.9 | DWS800 | 90 |
6.0 - 6.4 | DWS400 + DWS600 | 80 |
6.5 - 6.9 | DWS400 + DWS600 | 90 |
7.0 - 7.7 | 2 x DWS600 | 80 |
Area m2 | Heaters required | Spacing |
---|---|---|
7.8 - 8.4 | 2x DWS600 | 90 |
8.5 - 9.2 | DWS600 + DWS800 | 80 |
9.3 - 9.9 | DWS600 + DWS800 | 90 |
10.0 - 11.1 | 2 x DWS800 | 80 |
11.2 - 11.4 | 2 x DWS800 | 90 |
11.5 - 12.2 | DWS400 + DWS600 + DWS800 | 80 |
12.3 - 12.9 | DWS400 + DWS600 + DWS800 | 90 |
13.0 - 13.7 | 2 x DWS800 + DWS400 | 80 |
13.8 - 14.4 | 2 x DWS800 + DWS400 | 90 |
14.5 - 15.2 | 2 x DWS800 + DWS600 | 80 |
15.3 - 15.9 | 2 x DWS800 + DWS600 | 90 |
16.0 - 16.7 | 3 x DWS800 | 80 |
16.8 - 17.4 | 3 x DWS800 | 90 |
Installation
The Warmup Loose Wire System has been designed so that installation is quick and easy. However, as with all electrical underfloor heating systems, certain procedures must be followed. Ensure you have read all technical specifications and you are happy to fit Warmup Loose Wire Underfloor Heating to your room. To install your Warmup Underfloor Heating system follow these 4 steps. Please note that this is a summary.
- Smooth, clean and dry the subfloor surface. Paint the floor with Warmup Primer (you do not need to use primer if installing on an insulated tile back board). The light green colour of the primer will change to a dark green once dry. Avoid traffic once primer is down.
- Calculate in square metres the size of the area to be heated. Use the Sizing Guide (found in the back of the Installation Manual) to correctly fit your heating wire into the space provided. Layout the heating wire in parallel lines. Begin at the start point and in U shapes go to the furthest point. Using the wire spacing markings as tape down points, secure the heating wire to the floor with adhesive tape. Once completed, tape down the entire length of the heating wire, positioning the tape centrally over the wire.
- Follow the instructions supplied with your thermostat. Your underfloor heating system will not function without a correctly installed thermostat.
- Check if the heating wire is fully taped and secured. Grout the floor as soon as possible as per the manufacturersâ instructions. Tile as normal, taking care not to damage or dislodge the heating wire.
The heater can be installed without the need for specialist tools or expertise (in accordance with local building code). It is important, however, that the Warmup Thermostat be connected by a qualified electrician.